Strengths
Use
Packaging Unit
Mix Proportion
|
Construction Floor Plan
|
- KS F 3211 (2015) : Construction Film Waterproofing material
Item | Performance Standard | |||
---|---|---|---|---|
Tensile Performance | Tensile Strength Tensile Strength (N/㎜²) | Above 2.0 | ||
Coefficient of Expansion (%) | Above 550 | |||
Tensile Product (N/㎜) | Above 294.2 | |||
Tearing Performance | Tearing Strength (N/㎜) | Above 12.8 | ||
Reliability on Temperature | Tensile Strength Ratio (%) | -20 ℃ |
Above 100 | |
60 ℃ |
Above 35 | |||
Coefficient of Expansion between engagement portion during rupture (%) |
-20 ℃ |
Above 300 | ||
20 ℃ |
Above 350 | |||
60 ℃ |
Above 200 | |||
Heat Expansion Characteristic | Expansion Rate (%) | Above -4, Below 1 | ||
Tensile Performance | Tensile Strength Ratio(%) | Heat Treatment | Above 80, Below 150 | |
Promotional Exposure Distance | - |
|||
Alkali Treatment | Above 60, Below 150 | |||
Acid Treatment | - |
|||
Coefficient of Expansion (%) | Heat Treatment | Above 500 | ||
Promotional Exposure Treatment | - |
|||
Alkali Treatment | Above 500 | |||
Acid Treatment | - |
|||
Deterioration during Elongation | Heat Treatment | There shall be no fractured balance or apparent deformation of any test. |
||
Promotional Exposure Treatment | - |
|||
Ozone Treatment | - |
|||
Adhesion Performance | Untreated | N/㎜² |
Above 0.7 | |
After Repeated Cold Temperature Treatment | Above 0.5 | |||
Coating State | No lifting or detachment of the coating shall be allowed on any test specimen. |
|||
Fatigue Resistance | There shall be no perforation, tear, or fracture of the coating on any test specimen specifimen. |
|||
Flow Resistance Performance | Flow Length (㎜) | No more than 3 on any test specimen | ||
Crease Formation | Not on any test specimen. | |||
Solid (%) | Indicator Value ±3 |
1. Arranging Grounding Impregnation |
2. Apply Primer |
3. Mixing Urethane |
4. Apply urethane |